https://github.com/aptg/2022_dcpt_mice
Science Score: 13.0%
This score indicates how likely this project is to be science-related based on various indicators:
-
○CITATION.cff file
-
✓codemeta.json file
Found codemeta.json file -
○.zenodo.json file
-
○DOI references
-
○Academic publication links
-
○Academic email domains
-
○Institutional organization owner
-
○JOSS paper metadata
-
○Scientific vocabulary similarity
Low similarity (5.3%) to scientific vocabulary
Repository
Basic Info
- Host: GitHub
- Owner: APTG
- Language: Python
- Default Branch: main
- Size: 3.32 MB
Statistics
- Stars: 0
- Watchers: 3
- Forks: 0
- Open Issues: 2
- Releases: 1
Metadata Files
README.md
Mouse Water Phantom "MWP-2014-GSI"
This phantom was first used in ion beams 2014 at GSI, Darmstadt, then multiple times at IFJ-PAN in Krakow, and later at DCPT in Aarhus.
General description
- Walls made of PMMA. approx 1 cm thick.
- Isocenter located at entry surface of the water phantom.
- Z postive along beam direction, Y postive upwards, X positive from right to left as seen in beam direction.
Outer dimensions
- X-width: 449.5 mm Relative to isocenter: [-133.5; +316.0] mm
- Y-width: 249.5 mm Relative to isocenter: [-170.0; +79.5] mm
- Z-width: 344.5 mm Relative to isocenter: [ 0.0; +344.5] mm
Wall Thickness
- All 9.5 mm, except for YZ wall at positive X, which is 10.5 mm.
PMMA lid
- A PMMA plate act as a lid which may holds three mice over water.
- The PMMA lid may be displaced in 8 steps of 4.0 mm along the z-axis
- Two PMMA lids were designed:
- Revision 1 "2014-lid", including 2 holders for additional detectors
- Revision 2 "2016-lid"
- Thickness of lid: 0.50 mm rev 1 and 2
- In this simulation a solid lid will be modeled
- X-width: 248.0 mm Relative to isocenter: [ -124.0; +124.0] mm
- Y-width: 5.0 mm Relative to isocenter: [ +14.5; +19.5] mm
- Z-width: 182.5 mm Relative to isocenter: [ +9.5; +192.0] mm
Water level
- until surface of the PMMA lid, i.e.: Y: [-160.5; +19.5] mm
Brass collimator:
- X-width: 123.7 mm Relative to isocenter: [-82.0; +41.7] mm can be shifted up to +3 mm, not precise
- Y-width: 46.0 mm Relative to isocenter: [+14.5; +60.5] mm can be adjusted, here matched PMMA lid underside
Z-width: 19.5 mm Relative to isocenter: [+37.5; +57.0] mm at position 1, follows pos 1-8 in 4 mm steps.
Top of brass block has a Z-width reduction from 19.5 mm 15.5 mm, to allow space for mouse tail. This extrusion is 89.0 mm wide, 14.0 mm from the bottom of the collimator and 17-18 mm from the two edges of the brass block along X.
Nominal scoring positions
- Each bin for averaging is 4x4x4 mm wide.
- 8 positions along z axis, measured from phantom surface where beam enters:
- first bin: [65.0; 69.0] mm (position 1)
- last bin: [97.0; 101.0] mm (position 8)
- lateral scoring width is 1 cm along X and Y for good statistics and safely assuming lateral equilibrium
PTV
Noinal PTV extension, relative to isocenter, beam traveling along Z axis. Y is vertical, positive upwards. - x = [-50.0; 50.0] mm - y = [-12.5; 7.5] mm - z = [ 50.0; 85.0] mm
Directory structure
https://drivendata.github.io/cookiecutter-data-science/
Owner
- Name: Aarhus Particle Therapy Group
- Login: APTG
- Kind: organization
- Email: niels.bassler@gmail.com
- Location: Aarhus University, Denmark
- Website: www.phys.au.dk/aptg
- Repositories: 7
- Profile: https://github.com/APTG
GitHub Events
Total
- Push event: 2
- Create event: 1
Last Year
- Push event: 2
- Create event: 1