SenAOReFoc
SenAOReFoc: A Closed-Loop Sensorbased Adaptive Optics and Remote Focusing Control Software - Published in JOSS (2022)
Science Score: 95.0%
This score indicates how likely this project is to be science-related based on various indicators:
-
○CITATION.cff file
-
✓codemeta.json file
Found codemeta.json file -
✓.zenodo.json file
Found .zenodo.json file -
✓DOI references
Found 24 DOI reference(s) in README and JOSS metadata -
✓Academic publication links
Links to: joss.theoj.org -
✓Committers with academic emails
2 of 3 committers (66.7%) from academic institutions -
○Institutional organization owner
-
✓JOSS paper metadata
Published in Journal of Open Source Software
Scientific Fields
Repository
A closed-loop sensorbased adaptive optics and remote focusing control software that works with a deformable mirror and a Shack-Hartmann wavefront sensor.
Basic Info
Statistics
- Stars: 13
- Watchers: 3
- Forks: 1
- Open Issues: 0
- Releases: 1
Metadata Files
README.md
User guide for SenAOReFoc
Introduction
SenAOReFoc is a closed-loop sensorbased adaptive optics (AO) and remote focusing control software that works with a deformable mirror (DM) and a Shack-Hartmann wavefront sensor (SHWS). It provides a user-friendly graphic user interface (GUI) with modular widget arrangements and clear labelling to help the user navigate through different software functionalities. Interactive messages are also displayed from the GUI for user guidance.
SenAOReFoc consists of 5 main units, the SHWS initialisation and DM calibration unit, the Zernike aberration input unit, the AO control and data collection unit, the miscellaneous control unit, and the remote focusing unit. The software can be ran in either 'debug mode' to perform functionality tests without connected hardware (DM and SHWS), or 'standard mode' on a well-aligned optical sectioning microscope (confocal, multiphoton, etc.). User controllable system parameters can be freely accessed and modified in a separate configuration file that is loaded upon software initialisation, and parameters that require continuous user input can be modified from the GUI. Parameters calculated when running the software, as well as important result data, are grouped and saved in a separate HDF5 file that can be read with HDFView software. Automated AO performance characterisations can be performed in 'standard mode' to assess the correction ability of the optical system. If the adopted DM is designed with a large stroke, i.e., is capable of large deformations, both the closed-loop AO correction and remote focusing functionalities can be exploited. On the other hand, if the DM exhibits insufficient stroke for remote focusing, by ignoring the remote focusing unit, closed-loop AO correction functionalities will still be fully functional without additional modifications to the software.
Closed-loop AO correction can be performed using both the zonal method, which updates DM control voltages in terms of the raw slope values; and the modal method, which updates DM control voltages in terms of orthogonal Zernike polynomials. There are four sub-modes tagged to each of the two methods: 1) standard closed-loop AO correction; 2) closed-loop AO correction with consideration of obscured search blocks; 3) closed-loop AO correction with partial correction excluding defocus; and 4) closed-loop AO correction with both consideration of obscured search blocks and partial correction excluding defocus.
Remote focusing can be performed by scanning the focus axially with a pre-determined axial range, step increment and step number, or by manually adjusting a toggle bar on the GUI for random access remote focusing. The former also incorporates options of whether or not to perform closed-loop AO correction at each remote focusing depth.
The software has been validated on a reflectance confocal microscope. However, it should also be fully compatible with fluorescence microscope systems designed in a closed-loop configuration.
Scripts included in this folder and general descriptions
- app.py - Sets up GUI and event handlers, displays the GUI, instantiates devices such as DM and SHWS
- AO_slopes.py - Performs closed-loop AO correction via direct slopes (zonal correction)
- AO_zernikes.py - Performs closed-loop AO correction via Zernikes (modal correction)
- calibration_RF.py - Performs remote focusing calibration using closed-loop AO correction
- calibration_zern.py - Generates DM control matrix
- calibration.py - Performs DM calibration
- centroid_acquisition.py - Methods for centroiding of SH spots
- centroiding.py - Performs system aberration calibration
- config.py - Sets configuration file path
- config.yaml - Configuration file incorporating all system and static parameters (please change and add as needed according to the specific system)
- conversion.py - Performs slope - Zernike conversion
- data_collection.py - Performs automated characterisation of microscope AO performance
- HDF5_dset.py - Methods for generating and appending data to HDF5 datasets
- image_acquisition.py - Methods for image acquisition
- log.py - Method to set up event logs
- mirror.py - Performs DM initialisation
- SB_geometry.py - Performs initialisation of search block geometry
- SB_position.py - Performs repositioning of search blocks
- sensor.py - Performs SHWS initialisation
- SH_acquisition.py - Performs SHWS image acquisition
- zernike.py - Generates Zernike polynomials and derivatives
Installation instructions
You will need the following open-source software installed to function and modify SenAOReFoc:
- Python 3.7+: https://www.python.org/downloads/
Git: https://www.python.org/downloads/ For Linux/macOS, run:
bash git --versionand follow the instructions.A source-code editor (such as Visual Studio Code): https://code.visualstudio.com/
You will need open-source HDFView software installed to directly view data stored in the HDF5 file:
Once these are installed, create a local folder, navigate within that folder in the command prompt, and clone the source-code from the Git repository:
bash
git clone https://github.com/jiahecui/SenAOReFoc.git
Navigate within the 'SenAOReFoc' folder and set up a virtual environment (optional but recommended):
Windows:
bash
python -m venv venv
Linux/macOS:
bash
python3 -m venv venv
And activate the virtual environment:
Windows:
bash
venv\Scripts\activate
Linux/macOS:
bash
source venv/bin/activate
Then install all package dependencies:
bash
pip install -r requirements.txt
(macOS may need prior installation of 'wheel' module)
These include:
- numpy
- PySide2==5.13.2
- qimage2ndarray
- Click
- scipy==1.5.4
- h5py==2.9.0
- pyyaml
If using an older operating system, Pyside2==5.11.2 and h5py==2.6.0 are also operational with the current software.
And install the project in editable mode:
bash
pip install -e .
The current working example imports hardware APIs for Windows operating system. If using
macOS or Linux, please comment out all relevant lines in mirror.py, sensor.py,
and image_acquisition.py before proceeding, including:
python
from alpao.Lib64 import asdk
class MIRROR_ALPAO(asdk.DM)
from ximea import xiapi
class SENSOR_XIMEA(xiapi.Camera)
img = xiapi.Image()
To proceed with Ximea cameras using Linux, the corresponding Xiapi Python binding is required, which can be installed using the Ximea SDK installer found in
https://www.ximea.com/support/wiki/apis/XIMEA_Linux_Software_Package.
To proceed with Alpao DMs using Linux, Python 3.8 binding is currently required, the SDK installer of which can be found in
http://alpao.com/Download/AlpaoSDK
And packages for other Python versions will be soon be supported following their release.
Finally, SenAOReFoc can be run in standard mode in the availability of hardware devices (DM and SHWS):
Windows:
bash
python sensorbasedAO/app.py
macOS:
bash
python3 sensorbasedAO/app.py
As well as debug mode in the absence of hardware devices, which then sets up dummy devices for the purpose of testing software functionality:
Windows:
bash
python sensorbasedAO/app.py -d
macOS:
bash
python3 sensorbasedAO/app.py -d
Detailed descriptions of how to perform functionality tests in debug
mode without connected hardware can be found in the Software
functionality tests section.
After exiting the software, to also exit the virtual environment, in the command prompt run:
bash
deactivate
Software functionality tests
To perform functionality tests without hardware, leave all parameters in
config.yaml as default, run the software in debug mode, and
perform the following tests in sequence:
[Initialise SB]: A search block region should appear in the ImageViewer with 14 search blocks across the diameter. Message box:
Search block geometry initialised. Number of search blocks within the pupil is: 148.[Position SB]: A white dot should appear at the centre of all the search blocks. Message box:
Need to calibrate DM? [y/n]-> Click on the command prompt and pressyon the keyboard. Message box:Reposition search blocks using keyboard. Press arrow keys to centre S-H spots in search blocks. Press Enter to finish.-> Press↑,↓,←,→keys on the keyboard to reposition search blocks and pressEnterto confirm. Message box:Search block position confirmed.[Calibrate-S]: Message box:
Dummy DM actuator coordinates loaded.[S-Z Conv]: Message box:
Exiting slope - Zernike conversion process.[Calibrate-Z]: Message box:
Exiting Zernike control matrix calibration process.[Reset DM]: Message box:
DM reset success.Adjust the remote focusing toggle bar: Message box:
Focus position: X.X um.
The code coverage and effectiveness of the above functionality test can be measured
by installing coverage.py through the command prompt.
bash
pip install coverage
Then, run the software in debug mode by
bash
coverage run --source= sensorbasedAO\app.py -d
Perform the above functionality test, quit the software, then run in the command prompt again
bash
coverage report -m sensorbasedAO\app.py
And one should get a report that looks like the following with around 50% code coverage. This would be higher with more buttons tested and would be different when executing different functions in reality.
Getting started
After installing the software, please run SenAOReFoc in debug mode
and perform functionality tests according to the procedure given in the
Software functionality tests section.
Before running SenAOReFoc on the microscope system in standard mode
or modifying the software scripts, please first read the Notes for
development section at the bottom of this document and follow
instructions accordingly. Then, check the config.yaml file which
incorporates all system and static parameters required to correctly
function the software. Modifications should be made according to the
specific system and new parameters can be added as needed. All
parameters have been commented. The current example works with an
Alpao-69 DM and custom SHWS with a Ximea CMOS camera. In particular,
parameters that need to be modified for basic closed-loop AO correction
include:
```python camera: SN: "XXXXXXXX" exposure: 40000 # us framerate: 20.0 # Hz sensorwidth: 2048 # pixels sensorheight: 2048 # pixels sensordiam: 11.26 # mm Ximea binfactor: 2 # Ximea pixelsize: 5.5 # um Ximea
DM: SN: "XXXXXXXX" exercise: 0 # Flag for whether to exercise DM upon initialisation volmin: -0.1 # V Negative voltage to apply on DM during calibration volmax: 0.1 # V Positive voltage to apply on DM during calibration volbias: 0 # Neutral voltage of DM actuators settlingtime: 0.001 # DM membrane settling time
DM0: actuator_num: 69 # Alpao pitch: 1500 # um aperture: 10.5 # mm
relay: mirrorodd: 0 # Flag for whether there is an odd number of mirrors in between DM and lenslet relayodd: 0 # Flag for whether there is an odd number of relays in between DM and lenslet
lenslet: lensletpitch: 150 # um lensletfocal_length: 5200 # um
searchblock: pupildiam_0: 2.2 # mm Diameter of beam incident on SHWS
syscalib: syscalib_mode: 1 # Mode flag for system aberration calibration method, 0 -- load previous system aberration calibration profile, 1 -- perform new system aberration correction, 2 -- no system aberration correction
AO: zerngen: 0 # Flag for generating zernike modes on DM in AOzernikes.py and AOslopes.py, 0 - off, 1 - iterative generation loopmaxgen: 15 # Maximum number of loops for closed-loop control during generation of zernike modes reconcoeffnum: 69 # Number of zernike modes to use during wavefront reconstruction controlcoeff_num: 20 # Number of zernike modes to control during AO correction ```
Note that the DM exercise option may need to be set to 1 for
electromagnetic mirrors that observe substantial thermal effects [1],
which will start a process of sending random voltages within [-0.5,
0.5] to all DM actuators after pressing [Initialise SB]. After above
parameters have been modified, the procedures below can be performed for
basic closed-loop AO correction. Note that for a microscope using
reflectance contrast, this should be performed while scanning over a
small region on scattering samples to avoid specular reflections that
lead to the double-pass effect [2], which causes errors to the
aberration measurements. For fluorescence microscopes, a fluorescent
bead can be used as the sample with a static beam.
DM calibration:
On the GUI press [Initialise SB] -> Position SB -> [Calibrate-S] -> [S-Z Conv] -> [Calibrate-Z]
System aberration calibration:
To perform system aberration calibration anew, make sure the
corresponding mode flag is left as default in config.yaml.
python
sys_calib:
sys_calib_mode: 1 # Mode flag for system aberration calibration method, 0 -- load previous system aberration calibration profile, 1 -- perform new system aberration correction, 2 -- no system aberration correction
Then on the GUI press [Calibrate-Sys]. This will run closed-loop AO correction (zonal control) until the Strehl ratio is above the given tolerance factor (default Maréchal criterion 0.81), save final DM control voltages (DM system flat file) to the HDF5 file, and halt with the DM system flat file applied such that separate imaging can be performed.
To load a previous DM system flat file, change the corresponding mode
flag in config.yaml.
python
sys_calib:
sys_calib_mode: 0 # Mode flag for system aberration calibration method, 0 -- load previous system aberration calibration profile, 1 -- perform new system aberration correction, 2 -- no system aberration correction
Then on the GUI press [Calibrate-Sys]. This will automatically load the DM system flat file from last calibration session and halt with the DM system flat file applied.
To ignore system aberration correction for all subsequent closed-loop AO
correction processes, change the corresponding mode flag in
config.yaml.
python
sys_calib:
sys_calib_mode: 2 # Mode flag for system aberration calibration method, 0 -- load previous system aberration calibration profile, 1 -- perform new system aberration correction, 2 -- no system aberration correction
Then on the GUI press [Calibrate-Sys]. This will save the current centroid coordinates as the reference centroid coordinates for convergence during closed-loop AO correction.
Closed-loop AO correction:
Closed-loop AO correction can be performed without first generating
Zernike modes to the DM by setting the corresponding mode flag to its
default value in config.yaml.
python
AO:
zern_gen: 0 # Flag for generating zernike modes on DM in AO_zernikes.py and AO_slopes.py, 0 - off, 1 - iterative generation
Then, closed-loop AO correction can be performed using 2 different approaches, each with 4 different sub-modes, as explained in the functionality documentation below.
Alternatively, for characterisation purposes, Zernike modes can be first
applied to the DM before performing closed-loop AO correction by
changing the corresponding mode flag in config.yaml.
python
AO:
zern_gen: 1 # Flag for generating zernike modes on DM in AO_zernikes.py and AO_slopes.py, 0 - off, 1 - iterative generation
Functionality documentation
SHWS initialisation and DM calibration unit
[Initialise SB] determines the search block (SB) geometry given user informed parameters of the lenslet pitch (the actual diameter of one lenslet), the dimension and pixel size of the camera sensor, as well as the incident pupil diameter. This button also exercises the DM membrane by generating a user specified number of random patterns on the DM.
[Position SB] repositions the SB region on the camera sensor such that
it is concentric with the incident beam. This can be achieved in two
ways depending on whether or not the DM requires recalibration. User
input is needed at this stage by entering y or n on the
keyboard. By entering y, the user can reposition the SB region by
entering ↑, ↓, ←, → arrows on the keyboard, which will
shift the entire SB region by one pixel at a time and display it at its
new location. When the central SH spot(s) is centred within its
corresponding SB, by pressing Enter on the keyboard, the user can
confirm the new SB position and trigger the process of automatically
calculating new SB reference centroid coordinates. Upon entering n,
SB and DM calibration related parameters from the last session will be
automatically loaded from the HDF5 file.
[Calibrate-Sys] performs system aberration calibration in three modes. Mode 0 automatically loads the DM control voltages that correct for system aberrations (DM system flat file) from last calibration session onto the DM. Mode 1 runs closed-loop AO correction (zonal control) until the Strehl ratio is above the given tolerance factor and saves final DM control voltages (DM system flat file) to the HDF5 file. Mode 2 is designed to ignore system aberration correction for small stroke DMs by saving current centroid coordinates as reference for convergence during closed-loop AO correction.
[Calibrate-S] performs DM calibration to retrieve the control matrix (CM) for direct slopes (zonal) control. The positive and negative bias control voltages provided by the user are sequentially applied to each DM actuator to retrieve the x- and y-slope values, which are then used to calculate the DM influence function (IF) matrix and slope CM by computing its pseudo-inverse.
[S-Z Conv] calculates the conversion matrix between raw slope values and Zernike coefficients. This can be used to calculate the Strehl ratio for evaluation of the image quality during zonal control, or to further acquire the DM IF matrix and CM for modal control.
[Calibrate-Z] retrieves the CM for modal control by using results acquired in [Calibrate-S] and [S-Z Conv]. Before performing pseudo-inverse of the DM IF matrix, the results after singular value decomposition are first evaluated to identify a cut-off value for small singular values. This is usually selected as the value after which a significant drop is seen. System modes below this value are removed during pseudo-inverse for acquisition of a stable Zernike CM.
Zernike aberration input unit
The Zernike aberration input unit is mainly used for thorough characterisation of the system AO performance by specifying certain amounts of Zernike modes to generate on the DM membrane. Zernike modes are ordered according to the OSA/ANSI standard and piston is removed such that mode 1 starts with tip. [Zernike mode spin box] allows the user to specify a single mode number, the amplitude of which is given in [Zernike value spin box] in the unit of microns. Mode combinations can be specified in [Zernike array edit box] by providing an array of coefficients in the correct mode order. Irrelevant modes can be set as zero and only modes up to the maximum mode number controlled during AO correction (user-defined) can be generated.
AO control and data collection unit
This is the core software unit responsible for closed-loop AO control and automated data collection. Both Zernike (modal) and direct slopes (zonal) control can be performed in 4 different modes, which will be discussed below.
[Zernike AO 1] performs basic closed-loop modal AO control by updating DM control voltages with the Zernike CM obtained in [Calibrate-Z]. Sub-mode 1 does not generate Zernike aberrations modes before closed-loop AO correction. Sub-mode 2 generates aberrations specified in the Zernike aberration input unit on the DM membrane before performing closed-loop AO correction. The latter sub-mode is especially useful for simple characterisation of the system AO performance.
[Zernike AO 2] is a modified version of [Zernike AO 1] that takes into account missing or ill-formed spots (obscured SBs) detected by the SHWS due to arbitrarily shaped pupils [3-5].
[Zernike AO 3] is a modified version of [Zernike AO 1] that suppresses the correction of Zernike defocus such that refocusing of the focal spot is minimised.
[Slope AO 1] performs basic closed-loop zonal AO control by updating DM control voltages with the direct slope CM obtained in [Calibrate-S]. The 2 sub-modes described in [Zernike AO 1] also apply.
[Slope AO 2] is a modified version of [Slope AO 1] fulfilling the same purpose as [Zernike AO 2].
[Slope AO 3] is a modified version of [Slope AO 1] fulfilling the same purpose as [Zernike AO 3].
[Zernike Full] and [Slope Full] perform closed-loop AO control taking into account both obscured SBs and suppression of Zernike defocus at the same time.
[Data Collection] is designed to perform automated AO performance
characterisations of the microscope system, though any data collection
process that would benefit from automation can be written beneath the
hood. Each operation mode is identified by a unique mode flag in
config.yaml, which should be determined before software
initialisation. Example execution of automated AO performance
characterisations on a real microscope system can be found in the
Example usage section below.
Miscellaneous control unit
Independent image acquisition can be performed in 3 modes. [Live Acq] continuously acquires images and displays them on the GUI at the user-defined frame rate and exposure time until terminated by clicking the button a second time. [Burst Acq] acquires a user-defined number of frames in burst mode before automatic termination. [Single Acq] acquires only one image.
[Reset DM] resets the actuators to their neutral position. [Camera exposure time spin box] controls the exposure time of the SHWS given in units of microseconds. [Maximum loop no. spin box] determines the maximum number of iterations before termination of the AO control loop.
Remote focusing unit
The remote focusing unit controls all parameters and procedures relevant to the calibration and execution of remote focusing using a DM.
[CALIBRATE] triggers the calibration of DM control voltages for remote focusing. Calibration is performed by displacing a planar sample in incremental steps along the optical axis and compensating for the displacement using closed-loop AO correction. This allows system aberration at each remote focusing depth to be corrected for as well. For details of the remote focusing calibration process, please refer to [6,7]. The software performs this as a 2-step process that proceeds along the negative direction before the positive. The direction of calibration should be determined within the configuration file prior to software initialisation. Other important parameters include the number of and axial distance between incremental steps.
python
RF_calib:
calib_step_num: 11 # Number of steps used in one direction during calibration of remote focusing
calib_step_incre: 10 # um Axial increment between each step during calibration of remote focusing
calib_direct: 0 # Direction of calibration, 0-negative, 1-positive
Messages are displayed in the message box to inform users of the current
calibration direction and step number, as well as to provide users with
options to 1) confirm that the sample has been moved to the next
calibration step; and 2) save or discard calibrated voltages and exit
the thread. Commands can then be entered via the keyboard. A typical
example of the interactive command message is: Move sample to positive
position. Press [y] to confirm. Press [s] to save and exit. Press
[d] to discard and exit. The software automatically saves calibrated
voltages to the HDF5 file after reaching the maximum user-defined step
number or does so on request at an arbitrary step. After interpolation
of DM control voltages acquired at each calibration step, all remote
focusing voltages can then be loaded upon software initialisation.
[Scan Focus] controls whether remote focusing is to be performed at only one depth or at multiple depths. When unticked, only the first spin box on the left-hand-side panel is accessible while others are disabled. When ticked, the otherwise is true.
[MOVE] performs remote focusing at only one depth by first retrieving DM control voltages corresponding to that specified in [Focus Depth (microns)], and then applying those voltages on the DM to move the focus relative to the natural focal plane. Negative values move towards -z-axis and positive ones +z-axis.
[SCAN] performs remote focusing sequentially at multiple depths by applying different sets of voltages to the DM membrane and scanning the focus depth-wise. [Step Increment (microns)] controls the displacement interval between consecutive remote focusing planes, [Step Number] the number of planes to be accessed, [Start Depth (microns)] the depth at which to start the remote focusing process relative to the natural focal plane, and [Depth Pause Time (s)] the time for which the focal spot remains stable at each remote focusing plane. Entering a negative value for [Step Increment (microns)] permits remote focusing in the -z-direction.
[AO Correction Type] allows the user to choose whether or not to apply AO correction at each remote focusing plane and which type to apply. Four options are available from the drop box: [Zernike AO 3], [Zernike Full], [Slope AO 3], and [Slope Full], the features of which have been discussed above. All options are applicable to the remote focusing process behind both [MOVE] and [SCAN], default is set to [None].
[Remote focusing toggle bar] permits random access of different remote
focusing planes during imaging by simply dragging the bar to a desired
depth. Default is set to the natural focal plane and max/min limits are
provided by the user according to remote focusing calibration results by
changing the minimum and maximum value of the RFslider widget in Qt
Designer. The values are calculated as [depth (um) / step increment
(um)].

Example usage
Please refer to the metapaper associated with this software on arXiv for examples of automated AO performance characterisations on a real reflectance confocal microscope.
Notes for development
The current software assumes using an electromagnetic DM, where the actuator displacement is linearly proportional to the applied control voltage [8]. In this case, the device can be driven linearly in both the negative and positive directions by applying a normalised control voltage of
, where
is the maximum control voltage. However, if an electrostatic DM is to be used, the actuator displacement would be proportional to the square of the applied control voltage. In such a case, in order to drive the device linearly, the normalised control voltage should be given as
.
The SHWS used in the current example is custom built and uses a Ximea camera as the sensor. The interfacing of a different SHWS or different camera requires minor modifications of the software from two aspects: sensor instantiation and image acquisition. The former can be modified from
sensor.py, and a new class should be added for the new sensor in a similar way as the given example insensor.py. The latter can be modified fromimage_acquisition.py, and a new image instance should be created according to the specific sensor API.The DM used in the current example is an Alpao-69 DM. Similar as above, the interfacing of a different DM requires modifications of the software from two aspects: mirror instantiation and DM control commands. The former can be modified from
mirror.py, and a new class should be added for the new DM in a similar way as the given example inmirror.py. The latter should use new commands to replace where applicable:
python
self.mirror.Send(voltages)
self.devices['mirror'].Send(voltages)
self.mirror.Reset()
self.devices['mirror'].Reset()
Issues and support
Should any issues or problems be found in the software, please use the issue tracker at: https://github.com/jiahecui/SenAOReFoc/issues
To make general inquiries about how to use the software, or how to modify the software for integration into existing hardware, please email jiahe.cui@eng.ox.ac.uk
How to cite
If you're using any modified version of this software for your work, please cite the JOSS paper associated with this software by clicking the link at the top of this README file. If you're performing remote focusing using the calibration procedure set out in this software, please also cite either [6] https://doi.org/10.1364/boda.2021.dth2a.2 or [7] https://doi.org/10.1364/OE.442025.
Licence
GNU General Public License version 3 https://opensource.org/licenses/GPL-3.0.
References
U. Bitenc, "Software compensation method for achieving high stability of Alpao deformable mirrors," Opt. Express 25, 4368-4381 (2017). https://doi.org/10.1364/OE.25.004368
P. Artal, S. Marcos, R. Navarro, and D. R. Williams, "Odd aberrations and double-pass measurements of retinal image quality," J. Opt. Soc. Am. A 12, 195-201 (1995). https://doi.org/10.1364/JOSAA.12.000195
B. Dong and M. J. Booth, "Wavefront control in adaptive microscopy using Shack-Hartmann sensors with arbitrarily shaped pupils," Opt. Express 26, 1655-1669 (2018). https://doi.org/10.1364/OE.26.001655
J. Ye, W. Wang, Z. Gao, Z. Liu, S. Wang, P. Benítez, J. C. Miñano, and Q. Yuan, "Modal wavefront estimation from its slopes by numerical orthogonal transformation method over general shaped aperture," Opt. Express 23, 26208-26220 (2015). https://doi.org/10.1364/OE.23.026208
J. Cui, B. Dong, and M. J. Booth, "Shack-Hartmann sensing with arbitrarily shaped pupil (1.0)," Zenodo (2020). https://doi.org/10.5281/zenodo.3885508
J. Cui, R. Turcotte, K. Hampson, N. J. Emptage, and M. J. Booth, "Remote-Focussing for Volumetric Imaging in a Contactless and Label-Free Neurosurgical Microscope," in Biophotonics Congress 2021, C. Boudoux, K. Maitland, C. Hendon, M. Wojtkowski, K. Quinn, M. Schanne-Klein, N. Durr, D. Elson, F. Cichos, L. Oddershede, V. Emiliani, O. Maragò, S. Nic Chormaic, N. Pégard, S. Gibbs, S. Vinogradov, M. Niedre, K. Samkoe, A. Devor, D. Peterka, P. Blinder, and E. Buckley, eds., OSA Technical Digest (Optical Society of America, 2021), paper DTh2A.2 (2021). https://doi.org/10.1364/boda.2021.dth2a.2
J. Cui, R. Turcotte, N. J. Emptage, and M. J. Booth, "Extended range and aberration-free autofocusing via remote focusing and sequence-dependent learning," Opt. Express 29, 36660-36674 (2021). https://doi.org/10.1364/OE.442025
U. Bitenc, N. A. Bharmal, T. J. Morris, and R. M. Myers, "Assessing the stability of an ALPAO deformable mirror for feed-forward operation," Opt. Express 22, 12438-12451 (2014). https://doi.org/10.1364/OE.22.012438
Owner
- Name: Jiahe
- Login: jiahecui
- Kind: user
- Location: University of Oxford
- Repositories: 2
- Profile: https://github.com/jiahecui
JOSS Publication
SenAOReFoc: A Closed-Loop Sensorbased Adaptive Optics and Remote Focusing Control Software
Authors
Department of Engineering Science, University of Oxford, Parks Road, Oxford, OX1 3PJ, UK
Department of Engineering Science, University of Oxford, Parks Road, Oxford, OX1 3PJ, UK
Department of Engineering Science, University of Oxford, Parks Road, Oxford, OX1 3PJ, UK
Tags
Sensorbased Adaptive optics Remote focusing DM SHWSGitHub Events
Total
- Watch event: 2
Last Year
- Watch event: 2
Committers
Last synced: 11 months ago
Top Committers
| Name | Commits | |
|---|---|---|
| Jiahe Cui | j****i@e****k | 312 |
| Jiahe Cui | j****4@e****k | 33 |
| Kyle Niemeyer | k****r@f****m | 2 |
Committer Domains (Top 20 + Academic)
Issues and Pull Requests
Last synced: 6 months ago
All Time
- Total issues: 0
- Total pull requests: 1
- Average time to close issues: N/A
- Average time to close pull requests: about 9 hours
- Total issue authors: 0
- Total pull request authors: 1
- Average comments per issue: 0
- Average comments per pull request: 0.0
- Merged pull requests: 1
- Bot issues: 0
- Bot pull requests: 0
Past Year
- Issues: 0
- Pull requests: 0
- Average time to close issues: N/A
- Average time to close pull requests: N/A
- Issue authors: 0
- Pull request authors: 0
- Average comments per issue: 0
- Average comments per pull request: 0
- Merged pull requests: 0
- Bot issues: 0
- Bot pull requests: 0
Top Authors
Issue Authors
Pull Request Authors
- kyleniemeyer (1)
Top Labels
Issue Labels
Pull Request Labels
Dependencies
- Click *
- PySide2 ==5.13.2
- h5py ==2.9.0
- numpy *
- pyyaml *
- qimage2ndarray *
- scipy ==1.5.4
- Click *
- PySide2 ==5.13.2
- h5py ==2.9.0
- numpy *
- pyyaml *
- qimage2ndarray *
- scipy ==1.5.4