Recent Releases of peltier_controller
peltier_controller - Peltier Controller V1.3.1
Initial release of the Peltier Controller software.
This code is used to set up and control a measurement setup. The measurement setup contains a peltier element to set temperatures between -5 °C and 150 °C and a TFT touch display with SPI and the ILI9488 driver to display current information and to be able to configure and start tests. In addition, two external hydrogen sensors can be connected which output a voltage in relation to the hydrogen concentration. Furthermore, a custom chip with an integrated PT1000 is required to determine the current temperature of the Peltier element. A MAX31865 with the Adafruid PCB layout is used for this purpose.
To control the tests and adjust settings, the GUI is divided into four tabs. The first tab is the control tab. This tab can be used to manually set the temperature of the peltier element, to set the correct nominal temperature of the PT1000 and to start the measurement with the hydrogen sensors 1 and 2. In addition, this tab is used to monitor the LT8722 (peltier driver), as the current temperature, output voltage and output current are displayed.
The next tab is the tests tab. This tab is used to set different tests and to start them. In this tab it is possible to set the start and end temperature, the rise and fall time, the rise step size and fall step size and the number of test rounds.
The last two tabs are used for further monitoring of the LT8722. The status tab shows the status register of the LT8722. Possible errors are saved here. The control tab shows the control register of the LT8722, in which the current settings are stored.
- C++
Published by jan-kp 12 months ago